Cy5 and apc
WebCy5. Because of its broad absorption range and the fact that its emission spectra are equivalent to APC, PE-Cy5 is not recommended for simultaneous use with APC. The Cy5 molecule has been shown to exhibit nonspecific binding to Fc receptors, which is most …
Cy5 and apc
Did you know?
Web20 rows · Alexa Fluor dyes—Emission spectra. Figure 1. Emission spectra for Alexa Fluor dyes. Table 1. Properties of Alexa Fluor Dyes. * Typical emission color seen through the eyepiece of a conventional fluorescence … WebOct 9, 2016 · A synthetic methodology of preparing novel membrane stable, responsive dyes is revealed in this manuscript. 1,3-bis (arylimino)isoindole dyes were synthesized and their properties to undergo...
WebApr 10, 2024 · 一.产品描述Cy5-PEG-DBCO,Cyanine5-PEG-DBCO,花青素Cy5-聚乙二醇-二苯并环辛炔,Cy5 (Cyanine 5) 是一种发远红(far-red)荧光的花青素荧光染料,分为普通Cy5和磺化Cy5(Sulfo-Cy5)。它的消光系数很高,荧光很亮,并且对pH不敏感,一般可以用633 nm或647nm的激光束激发然后用Cy5或APC滤片观察,所以在绝大部分荧光仪器上 ... WebBD Biosciences Pharmingen has maximized the fluorochrome energy transfer in PE-Cy5, thus maximizing its fluorescence emission intensity, minimizing residual emission from PE, and minimizing lot-to-lot variation. PE-Cy5 is optimized for use with a single argon ion …
http://www.protocol-online.org/biology-forums/posts/42100.html WebMar 5, 2003 · The Cy5 component of PE-Cy5 can be excited independently, which it is, with the red diode. As Howard Shapiro pointed out in a previous email, Cy5 spectrally looks very much like APC. So the compensation will be very large. There is no easy fix for this.
Web- Allows the calibration of the FITC, PE, PE-TR, PE-Cy5, and APC channels in the flow cytometer with the same set of particles - Consists of set of several similar size particles with different fluorescence intensities in a convenient dropper bottle - Can be stored in the freezer and reused later since they can withstand repeated freezing and ...
WebAPC-Cy5.5 is a popular color used in flow cytometry. Its primary absorption peak is at 651 nm with emission peak at ~700 nm. AAT Bioquest also offers a unique ReadiUse™ Preactivated APC-Cy5.5 to facilitate the APC-Cy5.5 tandem conjugations to antibodies … home theatre reclining chairsWebThe first step of my whole project is to separate cells into different populations based on their markers so I will use multiple colours on them and it is hard to prevent overlaps. The other... hisense pureflat fmn440w20cWebThe Cy5 fluorophore is also the basis for the lipophilic neuronal and long-term DiD cell tracing reagents, which append alkyl tails (≥12 carbons) onto the core fluorophore. For stable signal generation, Alexa Fluor 647 dye is generally brighter than Cy5 dye in … hisense q8 specsWebApr 10, 2024 · 一.产品描述Cy5-PEG-DBCO,Cyanine5-PEG-DBCO,花青素Cy5-聚乙二醇-二苯并环辛炔,Cy5 (Cyanine 5) 是一种发远红(far-red)荧光的花青素荧光染料,分为普通Cy5和磺化Cy5(Sulfo-Cy5)。它的消光系数很高,荧光很亮,并且对pH不敏感,一般可 … hisense pureflat rf632n4bbf 70/30WebThe APC excitation source is the red laser of the cytometer, while the PC5 source is the blue laser (but there is also a small PC5 excitation coming from red laser, which makes things complicated home theatre room setupWebJun 14, 2024 · The following is an example of a combination of fluorophores for a 6-color panel; FITC/Alexa Fluor 488, PE, PerCP-Cy5.5, PE-Cy7, APC/Alexa Fluor 647, and APC-Cy7/APC-H7). If you are using an 8-color panel, you can use the above fluorophores and simply supplement with AmCyan and Brilliant Violet 421. hisense pureflat rq758n4swi1 fridge freezerWebOct 8, 2015 · Brilliant Violet 421™ and Brilliant Violet 570™ are novel polymeric, highly sensitive fluorophores excited by the violet laser, for use in flow cytometry. These are ideal for producing antibody... hisense projector short throw